id summary reporter owner description type status priority milestone component version resolution keywords cc 1356 Range of refT and refL for MIP in 8.4.5.2.2 bheng "In Section 8.4.5.2.2, in the following sentence: ""For the generation of the reference samples refT[ x ] with x = 0..refW − 1 and refL[ y ] with y = 0..refH − 1, the following applies"" I think refW and refH should probably be replaced with nTbW and nTbH, respectively, since that would match up with the actual range over which refT and refL are derived in Equations (255) and (256). ""The reference samples refT[ x ] with x = 0..nTbW − 1 and refL[ y ] with y = 0..nTbH − 1 are assigned as follows: refT[ x ] = refUnfilt[ x ][ −1 ] (255) refL[ y ] = refUnfilt[ −1 ][ y ] (256)"" " defect closed minor spec VVC D10 vE fixed ksuehring bbross XiangLi fbossen jvet@…