﻿id	summary	reporter	owner	description	type	status	priority	milestone	component	version	resolution	keywords	cc
136	Potential bug in transform coefficient zero-out of large TUs	zhou		"non-zero transform coefficients found on the decoder side in the area outside the top-left 32x32 region of large TUs. For example, in

ParkRunning3_3840x2160_50fps_10bit_420_IBBBP_22_2.vvc

which is the 3rd sub-stream of the sequence parallel coded in RA cfg with QP = 22. 

The non-zero coefficient location is: 

Frame POC: 20        
Location of 64x64 CU inside the frame:    x = 1024  y = 704       
Location of non-zero COEF inside the TU:  x = 32  y = 16
Non-zero COEF value: 14
"	defect	closed	minor		VTM		fixed		ksuehring XiangLi fbossen jvet@…