﻿id	summary	reporter	owner	description	type	status	priority	milestone	component	version	resolution	keywords	cc
1409	Overflow processing 16 bit sequences if JVET_R0351_HIGH_BIT_DEPTH_ENABLED is not set	adybrowne		"At present VTM can process 16 bit input sources using 10 (or other) bits. The input reader automatically shifts right input data by the correct number of bits. However if JVET_R0351_HIGH_BIT_DEPTH_ENABLED is not set, the 16 bit unsigned data is read into a 16 bit signed array and the conversion to 10 bits is therefore incorrect.
