﻿id	summary	reporter	owner	description	type	status	priority	milestone	component	version	resolution	keywords	cc
299	VVC Draft 5 v7: minor corrections	geertv		"Minor suggested corrections:

7.3.7.10	Transform unit syntax
if( ( IntraSubPartitionsSplitType =  = ISP_NO_SPLIT  &&  !( cu_sbt_flag  &&  
			   ( ( subTuIndex  = = 0  &&  cu_sbt_pos_flag )  | |  
			      ( subTuIndex  = = 1  &&  !cu_sbt_pos_flag ) ) )  &&  
			   ( CuPredMode[ x0 ][ y0 ] != MODE_INTRA  | |  
			      tu_cbf_cb[ x0 ][ y0 ]  | |  tu_cbf_cb[ x0 ][ y0 ] ) )  | |  
			( IntraSubPartitionsSplitType != ISP_NO_SPLIT && 
			( subTuIndex < NumIntraSubPartitions − 1  | |  !InferTuCbfLuma ) ) )
=> second tu_cbf_cb -> tu_cbf_cr

			
8.4.1	General decoding process for coding units coded in intra prediction mode
1.	The variable MipSizeId[ x ][ y ] for x = xCb + cbWidth..xCb + cbWidth − 1 and  y = yCb..yCb + cbHeight − 1 is derived as follows:
=> x = xCb..xCb + cbWidth − 1


8.4.2	Derivation process for MIP mode
–	Otherwise, candMipModeX is derived using IntraPredModeY[ xNbX ][ yNbX ] and MipSizeId[ xCb ][ yCb ] as specified in Table 8-4.
=> Table 8-1

ii.	For i equal to 0 to 2, inclusive, when IntraPredModeY[ xCb ][ yCb ] is greater than or equal to candMipModeList[ i ], the value of IntraPredModeY[ xCb ][ yCb ] is incremented by one.
=> i = 0..2


8.4.5.2.2	MIP reference sample derivation process
The neighboring samples => neighbouring


8.4.5.2.7	Reference sample substitution process
3.	For x = 0..refW − 1, y = −1, when refUnfilt[ x ][ y ] is marked as ""not available for intra prediction"", the value of refUnfilt[ x ][ y ] is set equal to the value of refUnfilt[ x − 1 ][ y ].
=>
3.	For x = -refIdx..refW − 1, y = −1 - refIdx, when refUnfilt[ x ][ y ] is marked as ""not available for intra prediction"", the value of refUnfilt[ x ][ y ] is set equal to the value of refUnfilt[ x − 1 ][ y ].


8.4.5.2.11	Specification of INTRA_ANGULAR2..INTRA_ANGULAR66 intra prediction modes
If one or more of the following conditions is true, filterFlag is set equal to 0.
–	predModeIntra is equal to INTRA_ANGULAR2, INTRA_ANGULAR34 or INTRA_ANGULAR66
=> modes are missing:
-   refFilterFlag is equal to 1 (modes 0, −14, −12, −10, −6, 2, 34, 66, 72, 76, 78, 80)


If one mor more of the following conditions is true, filterFlag is set equal to 1:
=> If one or more


8.4.5.2.12	Specification of INTRA_LT_CCLM, INTRA_L_CCLM and INTRA_T_CCLM intra prediction mode
The number of available neighbouring chroma samples on the top and top-right numTopSamp and the number of available neighbouring chroma samples on the left and left-below nLeftSamp are derived as follows:
=> numTopSamp -> numSampT, nLeftSamp -> numSampL

2.	The neighbouring luma samples samples pY[ x ][ y ] are derived as follows:
=> remove 'samples'


8.5.6.6	Weighted sample prediction process for combined merge and intra prediction
Formula (8-804) => extra "")"" to be deleted
"	defect	closed	minor	VVC D5 v8	spec	VVC D5 v7	fixed		ksuehring bbross XiangLi fbossen jvet@…