﻿id	summary	reporter	owner	description	type	status	priority	milestone	component	version	resolution	keywords	cc
502	Mismatch between SW and Spec on PDPC to angular intra modes	huayg		"A spec error is found in Clause 8.4.5.2.14 on PDPC to angular intra modes. SW is correct.

Eq (8-258) should be changed from 
{{{
wT[ y ] = 32  >>  ( ( y  <<  1 )  >>  nScale )
}}}
to
{{{
wT[ y ] = ( y < ( 3 << nScale ) )  ?  32  >>  ( ( y  <<  1 )  >>  nScale ) : 0
}}}

Eq (8-265) should be changed from
{{{
wL[ x ] = 32  >>  ( ( x  <<  1 )  >>  nScale )
}}}
to
{{{
wL[ x ] = ( x < ( 3 << nScale ) )  ?  32  >>  ( ( x  <<  1 )  >>  nScale ) : 0
}}}

(Note that a related typo error in Eq (8-262) has been reported in Ticket #479.)
"	defect	closed	minor		spec	VVC D6 vE	invalid	PDPC	ksuehring bbross XiangLi fbossen jvet@…