Opened 4 years ago

Closed 4 years ago

#1174 closed defect (fixed)

wrong lambda for classH1 PQ coding with LumaLevelToDeltaQPMode=1 (nonCTC)

Reported by: taoranlu Owned by:
Priority: minor Milestone:
Component: VTM Version:
Keywords: Cc: ksuehring, XiangLi, fbossen, jvet@…

Description

classH1 PQ coding with non CTC setting LumaLevelToDeltaQPMode=1 has performance drop due to lambda change after merging of MR1126 to fix rate control. (https://vcgit.hhi.fraunhofer.de/jvet/VVCSoftware_VTM/-/merge_requests/1126).

A fix is provided in MR1739:
https://vcgit.hhi.fraunhofer.de/jvet/VVCSoftware_VTM/-/merge_requests/1739

Change history (1)

comment:1 Changed 4 years ago by fbossen

  • Resolution set to fixed
  • Status changed from new to closed
Note: See TracTickets for help on using tickets.