Opened 5 years ago
Closed 5 years ago
#416 closed defect (fixed)
Missing condition in 6.4.4 Derivation process for neighbouring block availability
Reported by: | Tomohiro Ikai | Owned by: | |
---|---|---|---|
Priority: | minor | Milestone: | |
Component: | spec | Version: | VVC D6 vE |
Keywords: | Cc: | ksuehring, bbross, XiangLi, fbossen, jvet@… |
Description
In 6.4.4 Derivation process for neighbouring block availability,
The following condition is missing in O2001 WD.
entropy_coding_sync_enabled_flag is equal to 1 and xNbY >> Log2CTBSize is greater than or equal to ( xCurr >> Log2CTBSize ) + 1
Note: the above condition is in N1001 WD but it seems the text was unintentionally removed when editing the availability process of O2001 WD.
Change history (1)
comment:1 Changed 5 years ago by bbross
- Resolution set to fixed
- Status changed from new to closed
Note: See TracTickets for help on using tickets.
Thanks for reporting and suggesting a fix.
This will be fixed in JVET-P2001-vA.