Opened 6 years ago

Closed 6 years ago

#83 closed defect (fixed)

Missing inter MTS code in VTM2.0.1

Reported by: aikiho Owned by:
Priority: minor Milestone: VTM-2.2
Component: VTM Version: VTM-2.0.1
Keywords: Cc: ksuehring, XiangLi, fbossen, jvet@…

Description

Inter MTS is not working in VTM2.0.1

EMT=3 in configure file should enable inter MTS in the VTM2.0.1, but inter MTS is not enabled with configure setting.

Compared with the related code in BMS2.0.1, codes in EncCu::xEncodeInterResidual to set CU-level on/off for MTS is missing in VTM2.0.1

Change history (4)

comment:1 Changed 6 years ago by ksuehring

VTM 2.0.1 was extracted from BMS by removing the JEM_TOOLS macro. The inter MTS code was not moved out of this macro during the implementation.

Vadim volunteered to provide a patch, but so far we have no estimate when this will be finished. It may only arrive after VTM/BMS 2.1.

comment:2 Changed 6 years ago by ksuehring

  • Version set to VTM-2.0.1

comment:3 Changed 6 years ago by ksuehring

I think this was corrected in VTM 2.2, right?

comment:4 Changed 6 years ago by ksuehring

  • Milestone set to VTM-2.2
  • Resolution set to fixed
  • Status changed from new to closed