Opened 4 years ago
Closed 4 years ago
#1444 closed defect (fixed)
incorrect decoding of scalable conformance streams
Reported by: | iole.moccagatta | Owned by: | |
---|---|---|---|
Priority: | major | Milestone: | VTM-12.2 |
Component: | VTM | Version: | VTM-11.2 |
Keywords: | conformance | Cc: | ksuehring, fbossen, jvet-conformance@…, XiangLi, jvet@… |
Description
Pictures with same POC value should be output one after another in increasing layer ID order. This bug is reported in https://jvet.hhi.fraunhofer.de/trac/vvc/ticket/1164 and it causing incorrect decoding of these conformance streams:
VPS_B_ERICSSON_1.zip
VPS_C_ERICSSON_1.zip
Attached conformance streams' OPL with correct decoding order, and OPL generated by VTM11.0 with incorrect decoding order.
Attachments (4)
Change history (6)
Changed 4 years ago by iole.moccagatta
Changed 4 years ago by iole.moccagatta
Changed 4 years ago by iole.moccagatta
Changed 4 years ago by iole.moccagatta
comment:1 Changed 4 years ago by fbossen
- Summary changed from incorrect decoding of conformance streams to incorrect decoding of scalable conformance streams
- Version changed from VTM-11.0 to VTM-11.2
comment:2 Changed 4 years ago by fbossen
- Milestone set to VTM-12.2
- Resolution set to fixed
- Status changed from new to closed
Note: See TracTickets for help on using tickets.
See https://vcgit.hhi.fraunhofer.de/jvet/VVCSoftware_VTM/-/merge_requests/2048