Description
In VTM, the end of brick is still signaled at the end of each CTU as an end_of_slice_segment_flag, whereas the specification signals it only at the end of a brick as an end_of_brick_one_bit.
Change history (1)
comment:1 Changed 5 years ago by forayr
- Resolution set to fixed
- Status changed from new to closed