Opened 5 years ago
Closed 5 years ago
#593 closed defect (fixed)
Number of inputs when invoking process 8.5.6.1 General
Reported by: | vdrugeon | Owned by: | |
---|---|---|---|
Priority: | minor | Milestone: | |
Component: | spec | Version: | |
Keywords: | Cc: | ksuehring, bbross, XiangLi, fbossen, jvet@… |
Description
When process 8.5.6.1 is invoked in 8.5.1 General decoding process for coding units coded in inter prediction mode, dmvrSAD is only listed as input to the process for luma (cIdx equal to 0), but not for chroma, so that the number of inputs is wrong when invoking the process for chroma (happens twice).
Change history (1)
comment:1 Changed 5 years ago by bbross
- Resolution set to fixed
- Status changed from new to closed
Note: See TracTickets for help on using tickets.
Thanks for reporting.
This will be fixed JVET-P2001-vB.